| Hard or Incomplete Indexing Shellplate not indexing smoothly.
1. Shellplate bolt adjusted too tight. Readjust 1/8 turn maximum.
2. Shellplate bolt tightens when shellplate turns.
a. Brass tipped set screw loose or missing.
3. Wrong size locator buttons.
4. Index pawl bent, worn or in backwards.
5. Dirt under shellplate.
a. Keep shellplate clean.
b. When replacing shellplate, bolt (13418) must be lubed with a
little all purpose grease.
6. Bent or broken shellplate.
7. Index ball (13891) and/or spring (14118) stuck, missing or
broken. Can also cause shellplate to turn backwards after indexing. |
|
8. Not taking full stroke on the handle.
9. Ring indexer (13677) worn or indexer lock (13411)
needs adjusted. Return spring damaged or missing.
10. Improper type of locator button for caliber.Handle movement difficult
1. Powder or other debris causing jamming of moving parts.
2. Link arm pins (13700) galled.
3. Main shaft (13485) dirty or dry.
a. Clean and lubricate with 30 wt oil.
4. Camming pin on black casefeed slide not lubed.
5. Primer cam worn causing primer indexing arm to drag and
stick.
6. Incorrect lubricant used. Do not use solvent blended
lubes. |