Caliber Conversion Section
(continued)
Step 5 Remove
the primers: Remove the primers only if you need to change to a different size or type of
primer.
1. Remove the shellplate (ref. Step 4).
2. Loosen and remove the two primer system bolts Figure
162.
3. Carefully lift the primer assembly away from the machine Figure 163.
4. Figure 164 Empty the remaining primers by
placing a finger over the primer shield cap, inverting the magazine and carefully pouring
the primers onto the primer flip tray. Put the primers back into their original box.
5. If any primers remain in the primer area (on the machine) carefully
remove them.
6. If you need to change the rotary primer disc go to Step 6. If
you only to need empty the primer magazine, reinstall the primer system at this time.
Note: About Steps 6, 7 and 8. If you're
changing from a large rifle/pistol primer to a small rifle/pistol primer or vice versa,
the rotary primer disc, primer magazine, and primer punch will have to be changed. This is
because each of these three items are designed specifically for either large rifle/pistol
primers or small rifle/pistol primers.
Step 6 Change
the rotary primer disc (see note above):
Note: The two different size rotary primer
discs are labeled L (large) and S (small).
1. Remove the shellplate (ref. Step 4).
2. Remove the primer system and empty the primer magazine (ref. Step 5).
3. Rotate the primer system upside down. Using an 1/8" Allen wrench
unscrew the primer support shim screw and remove the primer support shim screw and remove
the primer support shim Figure 165.
4. Remove the rotary primer disc Figure 166.
Make sure the detent ball remains in place.
5. Place the other rotary primer disc onto the disc pin.
6. Slip the primer support shim back into place and snug the screw.
7. Reinstall the primer system.
Step 7 Change the
primer magazine
1. Remove the Primer Early Warning System Figure 167.
2. Remove the primer shield cap Figure 168.
3. Remove the primer magazine by pulling it straight up Figure
169.
4. Insert the new primer magazine.
5. Replace the primer shield cap and Primer Early Warning System. |