Now that everything is bolted down and you understand the safety
precautions, you can proceed.
First, decide what caliber you want to reload and take the shellplate
(*#20079) from the caliber conversion box (see Figure 04). Now, in your parts box, find a bag containing; index ball
(#13891), shellplate bolt (#13794), index ball spring (#13997), set screw (#13923), and
index sprocket (#13720).
click on
image to see larger picture |
| Figure 4
This photo shows a complete caliber conversion; the powder funnel, shellplate and
locator buttons. |
Insert the index ball spring
(#13781) in the platform as shown in Figure 5.
click on image to see larger picture |
| Figure 5 This photo
shows the index ball spring and index ball being placed in the platform. |
|
|
Next set the index ball on top of the index ball spring. Now place the
shellplate (number up) over the index ball spring and index ball (see Figure 6).
click on image to see larger picture |
| Figure 6 Showing the
shellplate in its proper position: under the ejector wire with the shellplate number
up. |
Place the index sprocket on top of the
shellplate (making sure the locator buttons go into the corresponding holes in the
shellplate (see Figure 7).
click on image to see larger picture |
| Figure 7 This photo
shows the index star in its proper position: the locating tabs centered in the
shellplate. |
|