| The
casefeed spring (#13526) when adjusted correctly, will keep the cases from becoming lodged between the casefeed plate and the casefeed port. When
adjusting, position the spring as close as possible to the casefeed plate in a location
favoring the left side of center |
|
in
relation to the port opening. Allow one case diameter (in perspective to the caliber) for
clearance between the spring and the leading edge of the exit port. Note that the spring
becomes the wall the case will hit it before falling down the funnel. |